2004
Abushakra, Bass, Iain S. Walker, and Max H. Sherman."Compression Effects on Pressure Loss in Flexible HVAC Ducts."HVAC&R Research Journal
10 (2004) 275-290.
Walker, Iain S.."Improving Air Handler Efficiency in Houses."ACEEE Summer Study on Energy Efficiency in Buildings
1 (2004) 341-352.
Walker, Iain S., Max H. Sherman, and Darryl J. Dickerhoff."Reducing Uncertainty for the DeltaQ Duct Leakage Test."
(2004).
McWilliams, Jennifer A., and Iain S. Walker."A systems approach to retrofiting residential HVAC systems."2004 ACEEE Summer Study on Energy Efficiency in Buildings
11 (2004) 119-129.
2003
Walker, Iain S.."Garbage Bags and Laundry Baskets."Home Energy Magazine
20.6 November/December (2003).
Walker, Iain S., and Michael D. Mingee."Reducing Air Handler Electricity Use: More Than Just a Better Motor."Home Energy Magazine
20.6 November/December (2003).
Walker, Iain S., Craig P. Wray, Cyril Guillot, and Sylvain Masson."Evaluation of Commercially Available Techniques and Development of Simplified Methods for Measuring Grille Airflows in HVAC Systems."
(2003).
Walker, Iain S., Douglas E. Brenner, Max H. Sherman, and Darryl J. Dickerhoff."Evaluation of PEGIT Duct Connection System."
(2003).
Wray, Craig P., Iain S. Walker, and Max H. Sherman."Guidelines for Residential Commissioning."
(2003).
Wray, Craig P., Iain S. Walker, and Max H. Sherman."Instrumented Home Energy Rating and Commissioning."
(2003).
Walker, Iain S., Jennifer A. McWilliams, and Steven J. Konopacki."Case Study Field Evaluation of a Systems Approach to Retrofitting a Residential HVAC System."
(2003).
Walker, Iain S., and Craig P. Wray."Evaluation of Flow Capture Techniques for Measuring HVAC Grille Airflows."ASHRAE Transactions
109 (2003).
Walker, Iain S., and Cyril Guillot."Experimental Evaluation of Gas Filled Plenum Duct Insulation."
(2003).
Walker, Iain S., Michael D. Mingee, and Douglas E. Brenner."Improving Air Handler Efficiency in Residential HVAC Applications."
(2003).
Siegel, Jeffrey A., and Iain S. Walker."Integrating ducts into the conditioned space: Successes and challenges."Architectural Engineering Institute Conference, Austin, TX
(2003).
Wray, Craig P., Iain S. Walker, Jeffrey A. Siegel, and Max H. Sherman."Practical Diagnostics for Evaluating Residential Commissioning Metrics."Lawrence Berkeley National Laboratory Report to the California Energy Commission
(2003).
Walker, Iain S., and Max H. Sherman."Sealant Longevity for Residential Ducts."Durability of Building and Construction Sealants and Adhesives
ASTM STP 1453 (2003).
2002
Walker, Iain S., and Max H. Sherman."An Easier Way to Measure Duct Leaks."Home Energy Magazine
19.5 September/October (2002).
Wray, Craig P., Iain S. Walker, and Max H. Sherman."Accuracy of flow hoods in residential applications."Proceedings of the ACEEE Summer Study on Energy Efficiency in Buildings, August 18-23, 2002
1 (2002) 339-350.
Walker, Iain S., Darryl J. Dickerhoff, and Max H. Sherman."The Delta Q method of testing the air leakage of ducts."Proceedings of the ACEEE Summer Study on Energy Efficiency in Buildings, August 18-23, 2002
1 (2002) 327-338.