Tools
CoE Data Center Energy Efficiency Toolkit
Click the light blue boxes in the diagram below to explore tools.
/* SVG by MDPRICE 2/16/2018 */ " horiz-adv-x="1196" d="M1083,641l-971,-415l0,179l769,319l-769,316l0,179l971,-410z"> a rect:hover { fill:#c5edd9; } Starthere! Energy AssessmentProcessManual PUE Estimator DC Pro EnergyAssessmentWorksheet AM Estimator AM Tool Power Chain Tool System-Level Assessment Tools Data Center Profiling Tools Report Findings & MakeRecommendations Master List ofEfficiencyActions Energy Assessment Report Template Data CenterEnergyAssessmentComplete! Collect Data ✓ Current PUE ✓ Potential PUE ✓✓ Current energy use distribution ✓ Potential energy use distribution ✓ Diagnose how energy is being usedand determine how to save energyand $$$! Document metrics, actions, andmeasurements from yourdata center Explore best practices Assess potential savings fromefficiency actions in the electricalpower chain This administrative manual willguide you through your energyassessment step by step! Optimize air management toaccelerate energy savings in datacenters without affecting the ITthermal environment Document your energy assessmentfindings and recommendations! ✓ Current energy use distribution✓ Key calculated metrics Recommended efficiency actions ✓✓ Rack cooling index interpretation ✓✓ Energy estimates for fans & chillers ✓ ✓ Recommended efficiency actions✓ IT Power Density & UPS Load Factor comparison Keep it simple(r) More detailTools presented here can be used sequentially to move from a basic understanding of how energy is used in your data center to identifying opportunities and implementing best practices.
We welcome user feedback on how to improve our suite of tools. Email us at [email protected]
CoE Resources ToolkitThis toolkit provides guidance and a logical sequence for users to employ the CoE Tools in order to achieve energy efficiency in their data centers. |
1. Data Center Profiler (DC Pro) ToolsThe DC Pro tools, DC Pro and the PUE Estimator are two "early stage" profiling tools designed for data center owners and operators to diagnose how energy is being used by their data centers and determine ways to save energy and money. |
2. Energy Assessment Process ManualManual that provides administrative step by step instructions for conducting an energy assessment (before, during, and after the assessment). |
3. Energy Assessment WorksheetExcel-based worksheet to document metrics, actions, and measurements from data center assessments. It is recommended that users first use the DC Pro tool before using this worksheet. |
4. Energy Assessment Kit Guide and SpecificationGuide that covers how a portable and temporary wireless mesh assessment kit can be used to speed up the energy assessment process, reduce the costs, and overcome the issues with respect to shutdowns. |
5. Air Management ToolsTwo Excel-based tools designed to optimize air management in data centers while enhancing energy efficiency. Both tools were intended to help users accelerate the energy savings in data centers without affecting the thermal IT equipment environment. |
6. Data Center Electrical Power Chain ToolExcel-based tool designed to help data center owners assess potential savings from efficiency actions in the electrical power chain of a data center. |
7. Energy Efficiency Assessment Report TemplateMicrosoft Word template for qualified assessors to report data center energy efficiency assessment findings. The document can easily be filled in with site data. An example assessment report using the template is also available here. |
8. Data Center Master List of Efficiency ActionsComprehensive list of both high-level and detailed best practices. It is recommended to utilize this list of best practices within an energy assessment report. |
Third-Party Tools & IncentivesThe Data Center Maturity Model, ENERGY STAR Portfolio Manager, the Free Cooling Calculator, and financial incentives are also available to help improve energy efficiency in data centers. |