Publications: Buildings
Reset Search
2018
Singh, Reshma, Paul A. Mathew, Jessica Granderson, Yash Shukla, Amiya Ranjan Behera, and Michael Pitt."Packaged Scalable Energy Information Systems for Hotels."Journal of Facilities Management
16.2 (2018) 119 - 141. DOI
2017
Kim, Yang-Seon, Iain S. Walker, and William W. Delp."Development of a Standard Test Method for Reducing the Uncertainties in Measuring the Capture Efficiency of Range Hoods."
(2017).
Walker, Iain S., Yang-Seon Kim, Brett C. Singer, and Wanyu R. Chan."Assessing Occupant and Outdoor Air Impacts on Indoor Air Quality in New California Homes."AIVC Conference
(2017). DOI
Rojas, Gabriel, Iain S. Walker, and Brett C. Singer."Comparing extracting and recirculating residential kitchen range hoods for the use in high energy efficient housing."AIVC Conference
(2017). DOI
Walker, Iain S., Gariel Rojas, Jordan D. Clark, and Max H. Sherman."Evaluating the Performance of Island Kitchen Range Hoods."AIVC Conference
(2017). DOI
Walker, Iain S., Max H. Sherman, Jordan D. Clark, and Gaelle Guyot."Residential Smart Ventilation: A Review."
(2017).
Less, Brennan, and Iain S. Walker."Smart Ventilation Controls for Occupancy and Auxiliary Fan Use Across U.S. Climates."
(2017).
2016
Singer, Brett C., William W. Delp, Douglas R. Black, and Iain S. Walker."Measured performance of filtration and ventilation systems for fine and ultrafine particles and ozone in an unoccupied modern California house."Indoor Air
(2016). DOI
Mills, Evan."Job Creation and Energy Savings Through a Transition to Modern Off-grid Lighting."Energy for Sustainable Development
33 (2016) 155-166. DOI
Granderson, Jessica, Samir Touzani, Claudine Y. Custodio, Michael D. Sohn, David A. Jump, and Samuel Fernandes."Accuracy of Automated Measurement and Verification (M&V) Techniques for Energy Savings in Commercial Buildings."Applied Energy
173 (2016) 296-308. DOI
Chan, Wanyu R., Yang-Seon Kim, Brett C. Singer, Iain S. Walker, and Max H. Sherman."Healthy Efficient New Gas Homes (HENGH) Field Study Protocol."
(2016).
Walker, Iain S., J. Chris Stratton, William W. Delp, and Max H. Sherman."Development of a Tracer Gas Capture Efficiency Test Method for Residential Kitchen Ventilation."
(2016).
Mills, Evan."Identifying and Reducing the Health and Safety Impacts of Fuel-Based Lighting."Energy for Sustainable Development
30 (2016) 39-50. DOI
Less, Brennan, Iain S. Walker, and Sara Ticci."Development of Smart Ventilation Control Algorithms for Humidity Control in High-Performance Homes in Humid U.S. Climates."
(2016).
Chan, Wanyu R., Randy L. Maddalena, J. Chris Stratton, Toshifumi Hotchi, Brett C. Singer, Iain S. Walker, and Max H. Sherman."Healthy Efficient New Gas Homes (HENGH) Pilot Test Results."
(2016).
Less, Brennan, and Iain S. Walker."Smart Ventilation Control of Indoor Humidity in High Performance Homes in Humid U.S. Climates."ASHRAE
(2016).
2015
Singh, Reshma, Baptiste Ravache, and Spencer M. Dutton."CLIMATE-SPECIFIC MODELING AND ANALYSIS FOR BEST-PRACTICE INDIAN OFFICE BUILDINGS."BS2015: 14th Conference of International Building Performance Simulation Association
(2015).
Yan, Da, William O'Brien, Tianzhen Hong, Xiaohang Feng, H. Burak Gunay, Farhang Tahmasebi, and Ardeshir Mahdavi."Occupant Behavior Modeling for Building Performance Simulation: Current State and Future Challenges."Energy and Buildings
107 (2015) 264-278. DOI
Hong, Tianzhen, Simona D'Oca, William J. N. Turner, and Sarah C. Taylor-Lange."An Ontology to Represent Energy-related Occupant Behavior in Buildings Part I: Introduction to the DNAs Framework."Building and Environment
92 (2015) 764-777. DOI
Mills, Evan, Jessica Granderson, Wanyu R. Chan, Richard C. Diamond, Philip Haves, Bruce Nordman, Paul A. Mathew, Mary Ann Piette, Gerald Robinson, and Stephen E. Selkowitz."Green, Clean, & Mean: Pushing the Energy Envelope in Tech Industry Buildings."
(2015).
Granderson, Jessica, Phillip N. Price, Stephen Czarnecki, Janie Page, Richard E. Brown, and Mary Ann Piette."Development of Diagnostic and M&V Agents, and Implementation in an Occupied Office Environment."
(2015).
D'Oca, Simona, and Tianzhen Hong."Occupancy Schedules Learning Process Through a Data Mining Framework."Energy and Buildings
88 (2015) 395-408. DOI
Logue, Jennifer M., William J. N. Turner, Iain S. Walker, and Brett C. Singer."A simplified model for estimating population-scale energy impacts of building envelope air-tightening and mechanical ventilation retrofits."Journal of Building Performance Simulation
9.1 (2015). DOI