Publications: BTUS Energy Analytics
Reset Search
2021
Gerber, Daniel L., Fariborz Musavi, Omkar Ghatpande, Stephen M. Frank, Jason Poon, Richard E. Brown, and Wei Feng."A Comprehensive Loss Model and Comparison of AC and DC Boost Converters."Energies
14.11 (2021) 3131. DOI
Booten, Chuck, Prakash Rao, Vi H. Rapp, Roderick Jackson, and Ravi S. Prasher."Theoretical Minimum Thermal Load in Buildings."Joule
5.1 (2021) 24 - 46. DOI
2020
Fierro, Gabe, Marco Pritoni, Moustafa Abdelbaky, Daniel Lengyel, John Leyden, Anand Prakash, Pranav Gupta, Paul Raftery, Therese Peffer, Greg Thomson, and David Culler."Mortar: An Open Testbed for Portable Building Analytics."ACM Transactions on Sensor Networks
16.1 (2020) 1 - 31. DOI
Liu, Jingjing, and Norman Bourassa."Continuously Improving Energy and Water Management."ASHRAE Journal
(2020). DOI
Cho, Brian, Teresa Dayrit, Yuan Gao, Zhe Wang, Tianzhen Hong, Alex Sim, and Kesheng."Effective Missing Value Imputation Methods for Building Monitoring Data."IEEE BigData 2020
(2020). DOI
Mathew, Paul A., Alison Farmer, and Jacob Werner."Best Practices Guide: Benchmarking Energy Efficiency in Laboratories."
(2020).
Fierro, Gabe, Anand Prakash, Cory Mosiman, Marco Pritoni, Paul Raftery, Michael Wetter, and David Culler."Interactive Metadata Integration with Brick."BuildSys '20: Proceedings of the 7th ACM International Conference on Systems for Energy-Efficient Buildings, Cities, and Transportation
(2020). DOI
Bergmann, Harry, Cory Mosiman, Avijit Saha, Selam Haile, William Livingood, Steven Bushby, Gabe Fierro, Joel Bender, Michael Poplawski, Jessica Granderson, and Marco Pritoni."Semantic Interoperability to Enable Smart, Grid-Interactive Efficient Buildings."2020 Summer Study on Energy Efficiency in Buildings
(2020). DOI
Fierro, Gabe, Anand Prakash, Cory Mosiman, Marco Pritoni, Paul Raftery, Michael Wetter, and David Culler."Shepherding Metadata Through the Building Lifecycle."BuildSys '20: Proceedings of the 7th ACM International Conference on Systems for Energy-Efficient Buildings, Cities, and Transportation
(2020). DOI
Pritoni, Marco, Anand Prakash, David H. Blum, Kun Zhang, Rui Tang, and Jessica Granderson."Advanced control sequences and FDD technology. Just shiny objects, or ready for scale?."ACEEE Summer Study 2020
(2020). DOI
Langevin, Jared, Aven Satre-Meloy, and Lyla Fadali."Attaching public health benefits to building efficiency measures at the national and regional scales."2020 ACEEE Summer Study on Energy Efficiency in Buildings
(2020).
Lin, Guanjing, Marco Pritoni, Yimin Chen, Jessica Granderson, Ricardo Moromisato, and Stephen Kozlen."Can We Fix It Automatically? Development of Fault Auto-Correction Algorithms for HVAC and Lighting Systems."ACEEE Summer Study
(2020). DOI
Fernandes, Samuel, Eliot Crowe, Samir Touzani, and Jessica Granderson."Detecting the undetected: Dealing with non-routine events using advanced M&V meter-based savings approaches."ACEEE Summer Study on Energy Efficiency in Buildings
(2020). DOI
Liu, Jingjing, Rongxin Yin, Marco Pritoni, Mary Ann Piette, and Monica Neukomm."Developing and Evaluating Metrics for Demand Flexibility in Buildings: Comparing Simulations and Field Data."ACEEE Summer Study
(2020). DOI
Bergfeld, Katie, Paul A. Mathew, Marshall Duer-Balkind, James Perakis, Pegah Noori khah, Travis Walter, and Andrew Held."Making Data-Driven Policy Decisions for the Nation’s First Building Energy Performance Standards."ACEEE Summer Study on Buildings 2020
(2020). DOI
Alstone, Peter, Richard E. Brown, Marco Pritoni, David H. Blum, Kun Zhang, and Anand Prakash."Resilient buildings for fire-adapted landscapes: EE and flexible loads integrated with solar and storage microgrids."ACEEE Summer Study 2020
(2020).
Chen, Yimin, Eliot Crowe, Guanjing Lin, and Jessica Granderson."What's in a Name? Developing a Standardized Taxonomy for HVAC System Faults."2020 ACEEE Summer Study on Energy Efficiency in Buildings
(2020). DOI
Prakash, Anand, Kun Zhang, Pranav Gupta, David H. Blum, Marc Marshall, Gabe Fierro, Peter Alstone, James Zoellic, Richard E. Brown, and Marco Pritoni."Solar+ Optimizer: A Model Predictive Control Optimization Platform for Grid Responsive Building Microgrids."Energies
13.12 (2020) 3093. DOI
Lin, Guanjing, Hannah Kramer, and Jessica Granderson."Building fault detection and diagnostics: Achieved savings, and methods to evaluate algorithm performance."Building and Environment
168 (2020) 106505. DOI
Prakash, Anand, Samir Touzani, Mariam Kiran, Shreya Agarwal, Marco Pritoni, and Jessica Granderson."Deep Reinforcement Learning in Buildings: Implicit Assumptions and their Impact."RLEM'20: Proceedings of the 1st International Workshop on Reinforcement Learning for Energy Management in Buildings & Cities
(2020). DOI
2019
Piette, Mary Ann, Reshma Singh, and Anand Prakash."Evaluation of the Need for and Design of a City Energy Operations System."Proceedings of the 1st ACM International Workshop on Urban Building Energy Sensing, Controls, Big Data Analysis, and Visualization - UrbSys'19
(2019). DOI
Singh, Reshma, Paul A. Mathew, Jessica Granderson, and Yash Shukla."Energy Information Systems: From the Basement to the Boardroom."
(2019). DOI
Singh, Reshma, Mary Ann Piette, Ashok J. Gadgil, Rajan Rawal, Narendra Bansal, Vishal Garg, Jyotirmay Mathur, Philip Haves, Paul A. Mathew, Christian Kohler, Mahabir Bhandari, Gail Brager, Vivian Loftness, Narendran Nadarajah, Ronnen M. Levinson, Richard E. Brown, Andre Desjarlais, Milind Rane, Sanyogita Manu, Yash Shukla, and Mona Doctor-Pingel."R&D and Implementation Outcomes From The U.S.-India Bilateral Center For Building Energy Research And Development Program."
(2019). DOI