Publications
2022
Wetter, Michael, Paul Ehrlich, Antoine Gautier, Milica Grahovac, Philip Haves, Jianjun Hu, Anand Prakash, Dave Robin, and Kun Zhang."OpenBuildingControl: Digitizing the control delivery from building energy modeling to specification, implementation and formal verification."Energy
238 (2022) 121501. DOI
2021
Sun, Kaiyu, Wanni Zhang, Zhaoyun Zeng, Ronnen M. Levinson, Max Wei, and Tianzhen Hong."Passive cooling designs to improve heat resilience of homes in underserved and vulnerable communities."Energy and Buildings
252 (2021) 111383. DOI
Baudette, Maxime, Jaimie Swartz, Keith Moffat, Jasper Pakshong, Leo Chu, Christoph Gehbauer, and Alexandra von Meier."Hardware-In-the-Loop Benchmarking Setup for Phasor Based Control Validation."
(2021). DOI
Putra, Handi Chandra, and Tianzhen Hong."Application of the DNAS framework expansion to occupant population synthesis."IBPSA Building Simulation Conference 2021
(2021).
Blum, David, Javier Arroyo, Sen Huang, Ján Drgoňa, Filip Jorissen, Harald Taxt Walnum, Yan Chen, Kyle Benne, Draguna Vrabie, Michael Wetter, and Lieve Helsen."Building optimization testing framework (BOPTEST) for simulation-based benchmarking of control strategies in buildings."Journal of Building Performance Simulation
14.5 (2021) 586 - 610. DOI
Chen, Yimin, Guanjing Lin, Eliot Crowe, and Jessica Granderson."Development of a Unified Taxonomy for HVAC System Faults."Energies
14 (2021).
Touzani, Samir, Marc Wudunn, Samuel Fernandes, Avideh Zakhor, Rohullah Najibi, and Jessica Granderson."A MACHINE LEARNING APPROACH TO ESTIMATE WINDOWS-TO-WALL RATIO USING DRONE IMAGER."
(2021).
Wetter, Michael, Jianjun Hu, Anand Prakash, Paul Ehrlich, Gabe Fierro, Milica Grahovac, Marco Pritoni, Lisa Rivalin, and Dave Robin."Modelica-json: Transforming energy models to digitize the control delivery process."IBPSA Building Simulation Conference 2021
(2021).
Luo, Na, Marco Pritoni, and Tianzhen Hong."An overview of data tools for representing and managing building information and performance data."Renewable and Sustainable Energy Reviews
147 (2021) 111224. DOI
Luo, Na, Jared Langevin, and Handi Chandra Putra."Quantifying the effect of multiple demand response actions on electricity demand and building services via surrogate modeling."IBPSA Building Simulation Conference 2021
(2021).
Fuchs, Heidi, and Prakash Rao."Survey of Available Information on U.S. Manufacturing Wastewater and Energy Requirements for Reuse."
(2021). DOI
Newkirk, Alexander, Prakash Rao, and Paul Sheaffer."U.S. Industrial and Commercial Motor System Market Assessment Report Volume 2: Advanced Motors and Drives Supply Chain Review."
(2021). DOI
McCall, James, Prakash Rao, Susana Garcia Gonzalez, Sachin Nimbalkar, Sujit Das, Sarang Supekar, and Joe Cresko."U.S. Manufacturing Water Use Data and Estimates: Current State, Limitations, and Future Needs for Supporting Manufacturing Research and Development."ACS ES&T Water
(2021). DOI
Hedman, Bruce, David Jones, and Vestal Tutterow."Beneficial CHP – Is that a Thing? Considering CHP in the Context of Beneficial Electrification."ACEEE Summer Study for Energy Efficiency in Industry
(2021).
Tutterow, Vestal, and Ethan Rogers."Energy Management and Product Sustainability Standards – A Key Link to Sustainable Supply Chains."ACEEE Summer Study for Energy Efficiency in Industry
(2021).
Hong, Tianzhen, Yujie Xu, Kaiyu Sun, Wanni Zhang, Xuan Luo, and Barry Hooper."Urban microclimate and its impact on building performance: A case study of San Francisco."Urban Climate
38 (2021) 100871. DOI
Li, Han, Zhe Wang, Tianzhen Hong, Andrew Parker, and Monica Neukomm."Characterizing patterns and variability of building electric load profiles in time and frequency domains."Applied Energy
291 (2021) 116721. DOI
Gerber, Daniel L., Fariborz Musavi, Omkar Ghatpande, Stephen M. Frank, Jason Poon, Richard E. Brown, and Wei Feng."A Comprehensive Loss Model and Comparison of AC and DC Boost Converters."Energies
14.11 (2021) 3131. DOI
Butzbaugh, Joshua, Robert Hosbach, and Alan K. Meier."Miscellaneous electric loads: Characterization and energy savings potential."Energy and Buildings
241 (2021) 110892. DOI
Wei, Max, Sang Hoon Lee, Tianzhen Hong, Brian Conlon, Lucy McKenzie, Bob Hendron, and Alea German."Approaches to cost-effective near-net zero energy new homes with time-of-use value of energy and battery storage."Advances in Applied Energy
2 (2021) 100018. DOI
Putra, Handi Chandra, Tianzhen Hong, and Clinton Andrews."An ontology to represent synthetic building occupant characteristics and behavior."Automation in Construction
125 (2021) 103621. DOI
Wang, Zhe, Tianzhen Hong, Han Li, and Mary Ann Piette."Predicting city-scale daily electricity consumption using data-driven models."Advances in Applied Energy
2 (2021) 100025. DOI
Ferrando, Martina, Tianzhen Hong, and Francesco Causone."A simulation-based assessment of technologies to reduce heat emissions from buildings."Building and Environment
195 (2021) 107772. DOI
Helmns, Dre, David Blum, Armando Casillas, Anand Prakash, Jonathan Woolley, David Vernon, Caton Mande, Michael Woodcox, and Spencer M. Dutton."Towards a Techno-Economic Analysis of PCM-Integrated Hybrid HVAC Systems."6th International High Performance Buildings Conference at Purdue
(2021).
He, zhiyuan, Tianzhen Hong, and Siaw K. Chou."A framework for estimating the energy-saving potential of occupant behaviour improvement."Applied Energy
287 (2021) 116591. DOI