Reset Search
2021
Helmns, Dre, David Blum, Armando Casillas, Anand Prakash, Jonathan Woolley, David Vernon, Caton Mande, Michael Woodcox, and Spencer M. Dutton."Towards a Techno-Economic Analysis of PCM-Integrated Hybrid HVAC Systems."6th International High Performance Buildings Conference at Purdue
(2021).
Helmns, Dre, David H. Blum, Spencer M. Dutton, and Van P. Carey."Development and Validation of a Latent Thermal Energy Storage Model Using Modelica."Energies
14.1 (2021) 194. DOI
2020
Caubel, Julien J., Vi H. Rapp, Sharon S. Chen, and Ashok J. Gadgil."Practical design considerations for secondary air injection in wood-burning cookstoves: An experimental study."Development Engineering
5 (2020) 100049. DOI
2019
Gilbert, Haley E., Tom Jacobs, Seongeun Jeong, Melvin Pomerantz, Dev Millstein, Doug Norsby, Andrea Repinsky, and Ronnen M. Levinson."Heat Island Mitigation Assessment and Policy Development for the Kansas City Region."
(2019). DOI
Less, Brennan, Spencer M. Dutton, Iain S. Walker, Max H. Sherman, and Jordan D. Clark."Energy savings with outdoor temperature-based smart ventilation control strategies in advanced California homes."Energy and Buildings
194 (2019) 317 - 327. DOI
Levinson, Ronnen M., George A. Ban-Weiss, Paul Berdahl, Sharon S. Chen, Hugo Destaillats, Nathalie Dumas, Haley E. Gilbert, Howdy Goudey, Sébastien Houzé de l’Aulnoit, Jan Kleissl, Benjamin Kurtz, Yun Li, Yan Long, Arash Mohegh, Negin Nazarian, Matteo Pizzicotti, Pablo J. Rosado, Marion L. Russell, Jonathan L. Slack, Xiaochen Tang, Jiachen Zhang, and Weilong Zhang."Solar-Reflective “Cool” Walls: Benefits, Technologies, and Implementation."
(2019). DOI
Clark, Jordan D., Brennan Less, Spencer M. Dutton, Iain S. Walker, and Max H. Sherman."Efficacy of occupancy-based smart ventilation control strategies in energy-efficient homes in the United States."Building and Environment
156 (2019) 253 - 267. DOI
Less, Brennan, Spencer M. Dutton, Xiwang Li, Jordan D. Clark, Iain S. Walker, and Max H. Sherman."Smart Ventilation for Advance California Homes – Single Zone Technology Task."
(2019).
2017
Shehabi, Arman, Mohan Ganeshalingam, Laurèn DeMates, Paul A. Mathew, and Dale A. Sartor."Characterizing the Laboratory Market."
(2017).
Kim, Yang-Seon, Iain S. Walker, and William W. Delp."Development of a Standard Test Method for Reducing the Uncertainties in Measuring the Capture Efficiency of Range Hoods."
(2017).
Walker, Iain S., Yang-Seon Kim, Brett C. Singer, and Wanyu R. Chan."Assessing Occupant and Outdoor Air Impacts on Indoor Air Quality in New California Homes."AIVC Conference
(2017). DOI
Rojas, Gabriel, Iain S. Walker, and Brett C. Singer."Comparing extracting and recirculating residential kitchen range hoods for the use in high energy efficient housing."AIVC Conference
(2017). DOI
Walker, Iain S., Gariel Rojas, Jordan D. Clark, and Max H. Sherman."Evaluating the Performance of Island Kitchen Range Hoods."AIVC Conference
(2017). DOI
Walker, Iain S., Max H. Sherman, Jordan D. Clark, and Gaelle Guyot."Residential Smart Ventilation: A Review."
(2017).
Less, Brennan, and Iain S. Walker."Smart Ventilation Controls for Occupancy and Auxiliary Fan Use Across U.S. Climates."
(2017).
2016
Singer, Brett C., William W. Delp, Douglas R. Black, and Iain S. Walker."Measured performance of filtration and ventilation systems for fine and ultrafine particles and ozone in an unoccupied modern California house."Indoor Air
(2016). DOI
Berger, Michael A., Paul A. Mathew, and Travis Walter."Big Data Analytics in the Building Industry."ASHRAE Journal
(2016) 38-45.
Chan, Wanyu R., Yang-Seon Kim, Brett C. Singer, Iain S. Walker, and Max H. Sherman."Healthy Efficient New Gas Homes (HENGH) Field Study Protocol."
(2016).
Walker, Iain S., J. Chris Stratton, William W. Delp, and Max H. Sherman."Development of a Tracer Gas Capture Efficiency Test Method for Residential Kitchen Ventilation."
(2016).
Less, Brennan, Iain S. Walker, and Sara Ticci."Development of Smart Ventilation Control Algorithms for Humidity Control in High-Performance Homes in Humid U.S. Climates."
(2016).
Chan, Wanyu R., Randy L. Maddalena, J. Chris Stratton, Toshifumi Hotchi, Brett C. Singer, Iain S. Walker, and Max H. Sherman."Healthy Efficient New Gas Homes (HENGH) Pilot Test Results."
(2016).
Less, Brennan, and Iain S. Walker."Smart Ventilation Control of Indoor Humidity in High Performance Homes in Humid U.S. Climates."ASHRAE
(2016).
2015
Singh, Reshma, Baptiste Ravache, and Spencer M. Dutton."CLIMATE-SPECIFIC MODELING AND ANALYSIS FOR BEST-PRACTICE INDIAN OFFICE BUILDINGS."BS2015: 14th Conference of International Building Performance Simulation Association
(2015).
Mathew, Paul A., Laurel N. Dunn, Michael D. Sohn, Andrea C. Mercado, Claudine Custudio, and Travis Walter."Big-data for building energy performance: Lessons from assembling a very large national database of building energy use."Applied Energy
140 (2015) 85 - 93. DOI
Logue, Jennifer M., William J. N. Turner, Iain S. Walker, and Brett C. Singer."A simplified model for estimating population-scale energy impacts of building envelope air-tightening and mechanical ventilation retrofits."Journal of Building Performance Simulation
9.1 (2015). DOI