Reset Search
2016
Iyer, Maithili, Hannah Stratton, Sangeeta Mathew, Satish Kumar, Paul A. Mathew, and Mohini Singh."Review of Building Data Frameworks Across Countries: Lessons for India."
(2016).
Walker, Iain S., J. Chris Stratton, William W. Delp, and Max H. Sherman."Development of a Tracer Gas Capture Efficiency Test Method for Residential Kitchen Ventilation."
(2016).
Less, Brennan, Iain S. Walker, and Sara Ticci."Development of Smart Ventilation Control Algorithms for Humidity Control in High-Performance Homes in Humid U.S. Climates."
(2016).
Chan, Wanyu R., Randy L. Maddalena, J. Chris Stratton, Toshifumi Hotchi, Brett C. Singer, Iain S. Walker, and Max H. Sherman."Healthy Efficient New Gas Homes (HENGH) Pilot Test Results."
(2016).
Less, Brennan, and Iain S. Walker."Smart Ventilation Control of Indoor Humidity in High Performance Homes in Humid U.S. Climates."ASHRAE
(2016).
2015
Singh, Reshma, Baptiste Ravache, and Spencer M. Dutton."CLIMATE-SPECIFIC MODELING AND ANALYSIS FOR BEST-PRACTICE INDIAN OFFICE BUILDINGS."BS2015: 14th Conference of International Building Performance Simulation Association
(2015).
Yan, Da, William O'Brien, Tianzhen Hong, Xiaohang Feng, H. Burak Gunay, Farhang Tahmasebi, and Ardeshir Mahdavi."Occupant Behavior Modeling for Building Performance Simulation: Current State and Future Challenges."Energy and Buildings
107 (2015) 264-278. DOI
Hong, Tianzhen, Simona D'Oca, William J. N. Turner, and Sarah C. Taylor-Lange."An Ontology to Represent Energy-related Occupant Behavior in Buildings Part I: Introduction to the DNAs Framework."Building and Environment
92 (2015) 764-777. DOI
Taylor, Margaret, C. Anna Spurlock, and Hung-Chia Yang."Confronting Regulatory Cost and Quality Expectations: An Exploration of Technical Change in Minimum Efficiency Performance Standards."
(2015).
Mathew, Paul A., Laurel N. Dunn, Michael D. Sohn, Andrea C. Mercado, Claudine Custudio, and Travis Walter."Big-data for building energy performance: Lessons from assembling a very large national database of building energy use."Applied Energy
140 (2015) 85 - 93. DOI
D'Oca, Simona, and Tianzhen Hong."Occupancy Schedules Learning Process Through a Data Mining Framework."Energy and Buildings
88 (2015) 395-408. DOI
Logue, Jennifer M., William J. N. Turner, Iain S. Walker, and Brett C. Singer."A simplified model for estimating population-scale energy impacts of building envelope air-tightening and mechanical ventilation retrofits."Journal of Building Performance Simulation
9.1 (2015). DOI
Less, Brennan, Nasim A. Mullen, Brett C. Singer, and Iain S. Walker."Indoor Air Quality in 24 California Residences Designed as High-Performance Homes."
(2015). DOI
2014
Diamond, Richard C., and Wei Feng."Sustainability by Design: How One Building in China Could Change the World."
(2014).
Turner, William J. N., and Iain S. Walker."Energy and IAQ Implications of Residential Ventilation Cooling."
(2014).
Bonvini, Marco, Michael D. Sohn, Jessica Granderson, Michael Wetter, and Mary Ann Piette."Robust on-line fault detection diagnosis for HVAC components based on nonlinear state estimation techniques."Applied Energy
124 (2014) 156 - 166. DOI
Turner, William J. N., Iain S. Walker, and Max H. Sherman."Advanced Controls for Residential Whole-House Ventilation Systems."
(2014).
Less, Brennan, Iain S. Walker, and Yihuan Tang."Development of an Outdoor Temperature-Based Control Algorithm for Residential Mechanical Ventilation Control."
(2014).
Hult, Erin L., Henry Willem, Phillip N. Price, Toshifumi Hotchi, Marion L. Russell, and Brett C. Singer."Formaldehyde and acetaldehyde exposure mitigation in US residences: In-home measurements of ventilation control and source control."
(2014).
Brown, Richard E., Travis Walter, Laurel N. Dunn, Claudine Y. Custodio, and Paul A. Mathew."Getting Real with Energy Data: Using the Buildings Performance Database to Support Data-Driven Analyses and Decision-Making."
(2014).
Walker, Iain S., Max H. Sherman, and Brennan Less."Houses are Dumb without Smart Ventilation."
(2014).
Less, Brennan, and Iain S. Walker."Indoor Air Quality and Ventilation in Residential Deep Energy Retrofits."
(2014).
Turner, William J. N., and Iain S. Walker."Using a Ventilation Controller to Optimize Residential Passive Ventilation For Energy and Indoor Air Quality."
(2014).