Taming the Energy Use of Gaming Computers
Publication Type
Authors
DOI
Abstract
One billion people around the world engage in some form of digital gaming. Gaming is the most energy-intensive use of personal computers, and the high-performance “racecar” systems built expressly for gaming are the fastest growing type of gaming platform. Large performance-normalized variations in nameplate power ratings for gaming computer components available on today’s market indicate significant potential for energy savings: central processing units vary by 4.3-fold, graphics processing units 5.8-fold, power supply units 1.3-fold, motherboards 5.0-fold, and random access memory (RAM) 139.2-fold. Measured performance of displays varies by 11.5-fold. However, underlying the importance of empirical data, we find that measured peak power requirements are considerably lower than nameplate for most components tested, and by about 50 % for complete systems. Based on actual measurements of five gaming PCs with progressively more efficient component configurations, we estimate the typical gaming computer (including display) to use approximately 1400 kWh/year, which is equivalent to the energy use of ten game consoles, six standard PCs, or three refrigerators. The more intensive user segments could easily consume double this central estimate. While gaming PCs represent only 2.5 % of the global installed PC equipment base, our initial scoping estimate suggests that gaming PCs consumed 75 TWh/year ($10 billion) of electricity globally in 2012 or approximately 20 % of total PC, notebook, and console energy usage. Based on projected changes in the installed base, we estimate that consumption will more than double by the year 2020 if the current rate of equipment sales is unabated and efficiencies are not improved. Although they will represent only 10 % of the installed base of gaming platforms in 2020, relatively high unit energy consumption and high hours of use will result in gaming computers being responsible for 40 % of gaming energy use. Savings of more than 75 % can be achieved via premium efficiency components applied at the time of manufacture or via retrofit, while improving reliability and performance (nearly a doubling of performance per unit of energy). This corresponds to a potential savings of approximately 120 TWh/year or $18 billion/year globally by 2020. A consumer decision-making environment largely devoid of energy information and incentives suggests a need for targeted energy efficiency programs and policies in capturing these benefits.