Date Title Files and Links
Cooling Data Centers with Warm Water
Presentation from 5/27/2021 on cooling data centers with warm water.
Sartor IEEE Madison 052621 (1).pdf
Cooling Performance Testing of Attaway's Negative Pressure CDU
Attaway is a recently installed High-Performance Computing (HPC) machine at Sandia National Labs that is 70% water-cooled and 30% air-cooled.
206888r.pdf
Sandia HPC Liquid Cooling_Case Study_NREL_July 2021.pdf
Cooling the Data Center: Design of a Mechanical Controls Owner Project Requirements (OPR) Template
As the power demands of supercomputers continue to grow, so do the demands of the mechanical cooling systems that support the infrastructure and building in which the supercomputers reside.
Cooling the Data Center_ Design of a Mechanical Controls Owner Project Requirements (OPR) Template.pdf
Corrosion coupons may not be useful for predicting data center equipment failure rates
Paper presented at the Indoor Air Conference June 2011: Corrosion Coupons May Not Be Useful for Predicting Data Center Equipment Failure Rates Author(s): Coles, H.C., P.N. Price, T. Han, A. Gadgil, and B. Tschudi
Corrosion-Indoor-Air-2011-997v3.pdf
Corrosion Coupons May Not Be Useful for Predicting Data Center Equipment Failure Rates (Presentation)
Presentation at the Indoor Air Conference June 2011: Corrosion Coupons May Not Be Useful for Predicting Data Center Equipment Failure Rates Author(s): Han, T., H.C. Coles, P.N. Price, A.Gadgil, and B.Tschudi
Indoor-Air-997-Henry Coles-v3.pdf
Cray Hybrid XC30 Installation - Facilities Level Overview
This paper focuses on the site preparation and integration of the Cray Hybrid XC30 into a state of the art HPC data center from a facilities point of view. Author(s): McMurtrie, C., L. Gilly, and T. Belotti
CSCS Descrizione Colin Piz Daint.pdf
Creating a Data Center Efficiency Plan
This white paper demonstrates how to create a data center energy efficiency plan by outlining the required steps, overcoming common challenges, looking at what information is important and relevant in determining savings, and what factors to consider wh
FRE-Data-Center-Efficiency-Planning-Whitepaper.pdf
Data Center Air Management Estimator
The Data Center Air Management Estimator is a simplified version of the Air Management Tool that uses the same engine. The input options in this tool have been reduced in favor of increased clarity.   
AM Estimator Version 1-0_0.xls
Data Center Air Management Report
The purpose of this study is to demonstrate to data center designers and operators the operational and energy benefits of thoughtful and efficient data center air management techniques.
DC AIr Management Report_2006.pdf
Data Center Air Management Research
By applying a more rigorous methodology, this research focuses on how air management can be improved to save energy without negatively affecting the thermal IT-equipment environment and, in turn, the IT-equipment reliability.
AirManagement_Herrlin2010.pdf
Data Center Air Management Tool
The Data Center Air Management Tool (v.3) was developed to accelerate energy savings in data centers without affecting the thermal IT equipment environment by identifying opportunities through air management upgrades.
AM Tool v3.0 (3-15-23) Distribution.xls
Air Management Tool User Guide, Air Management Tool Data Collection Guide, Air Management Tool Engineering Reference Manual
Data Center Airflow Management Retrofit
As data center energy densities, measured in power-use per square foot, increase, energy savings for cooling can be realized by optimizing airflow pathways within the data center.
airflow-doe-femp.pdf
Data Center Assessments to Identify Efficiency Opportunities Presentation
Presentation that outlines a number of tools and strategies to aid practitioners in reducing energy consumption in datacenters. Author(s): Tschudi, B.
webcast_2008-1113_data_centers.pdf
Data Center Blueprint Summit 2019
Agenda and Attendance sheet from the  2019 Data Center Blueprint Summit held in Mumbai. 
CII Data Center Blueprint Summit_agenda_24Sep.pdf
Building Data - Attendance Sheet.pdf
Data Center Blueprint Summit Materials
Data Center Bluprint Summit | Mumbai | September 2019 Resources related to the Energy Efficiency in India Initiative from the “Building Data Center Ecosystem Conducive to India’s Digital Convergence” Data Center Blueprint Summit, held in Septe
CII Data Center Blueprint Summit_Agenda.pdf
CII Data Center Blueprint Attendance Sheet.pdf
A Joint Initiative of IGBC and LBNL US for Enhanced Energy Efficiency in Indian Data Centers.pdf
Making Datacenters Resilient and Efficient.pdf
Data is the Future, The Future is Datacentre.pdf
Delivering Business Value through Better Aligning Facility & IT.pptx
Data Center Case Study: Crown Castle
Case study on Crown Castle's recent data center energy efficiency upgrade, which leveraged available utility incentives.
111 8th Loop Optimization 2019.pdf
Data Center Economizer Contamination and Humidity Study
Project measured server equipment exposure to particulate matter in typical California data centers to better understand what level of particle concentration is actually present.
PG&E Economizer Contamination_2007.pdf
Data Center Economizer Cooling with Tower Water
A prototype computer equipment rack-level cooling device with two heat exchangers was demonstrated to illustrate an energy efficient cooling capability.
PIER_Economizer Cooling Demo_2012.pdf
Data Center Efficiency and IT Equipment Reliability At Wider Operating Temperatures and Humidity Ranges
Paper concludes that many data centers can realize overall operational cost savings by leveraging looser environmental controls within the wider range of supported temperature and humidity limits as established by equipment manufacturers.
WP50-Data Center Efficiency and IT Equipment Reliability at Wider Operating Temperature and Humidity Ranges.pdf
Data Center Energy Benchmarking: Part 1 - Case Studies on Two Co-location Data Centers (No. 16 and 17)
Case studies of data centers located in a four-story building in San Francisco, California (#16 and #17). General recommendations for improving overall energy efficiency of the data centers included improving the design, operation, and control of mechan
Benchmarking case study 16&17_2007.pdf
Data Center Energy Benchmarking: Part 2 - Case Studies on Two Co-location Network Data Centers (No. 18 and 19)
Case studies of two data centers within a co-location facility located on the sixth floor of a multi-story building in downtown Los Angeles, California (#18 and #19). General recommendations for improving overall data center energy efficiency include im
Benchmarking case study 18&19_2007.pdf
Data Center Energy Benchmarking: Part 3 - Case Study on an IT Equipment-testing Center (No. 20)
Case study of data center in multi-story office building in San Jose, California (#20). Since the data center was used only for testing equipment, it was not configured as a critical facility in terms of electrical and cooling supply. General recommenda
Benchmarking case study 20_2007.pdf
Data Center Energy Benchmarking: Part 4 - Case Study on a Computer-testing Center (No. 21)
Case study of data center in multi-story office building in San Jose, California (#21). Since the data center was used only for testing equipment, it was not configured as a critical facility in terms of electrical and cooling supply. General recommenda
Benchmarking case study 21_2007.pdf
Data Center Energy Benchmarking: Part 5 - Case Studies on a Corporate Data Center (No. 22)
Case study of data center located in an office building in Pasadena, California (#22). General recommendations for improving overall data center energy efficiency include improving the lighting control, airflow optimization, control of mechanical system
Benchmarking case study 22_2007.pdf
Data Center Energy Efficiency Best Practices Workshop
FEMP Flier-7-13.pdf